Javascript message

This site uses javascript. If javascript is disabled in your browser, some functionality may be impaired.

Nitrophenols

Separation of nitrophenols on Kromasil C18

  • 1 = phenol
    s00422
  • 2 = 2,4-dinitrophenol
    s00427
  • 3 = 4-nitrophenol
    s00424
  • 4 = 3-nitrophenol
    s00428
  • 5 = 2-nitrophenol
    s00432
chromatogram for g1106
Column:Kromasil 100-1.8-C18 2.1 × 50 mm
Part number:MF1CLD05
Eluent:acetonitrile / potassium phosphate in water, 5 mM, pH 4.5 [39.25/60.75]
Flow rate:0.6 ml/min
Temperature:35 °C
Detection:UV 230 nm

Reference

Nouryon application note

Kromasil columns available with the stationary phase used in this application

Click/touch the dot for the combination of stationary phase and column diameter of your interest to access column length availability and further options.
Column diameters, [mm]
FamilyPhasedp [μm]2.13.0
100 ÅC181.8 MF1CLD__ MF1CLC__